AD-A2606-02
Aidear
Aluminium
220V-460V
Up to 1.5MPa
100 kg
12 months
Microchannel Heat Exchanger
-40°C ~+150°C
Condensation / Evaporation / Cooling
Data Center /Dry Cooler / Water Chiller Unit / AHU/Dry equipment
| Availability: | |
|---|---|
| Quantity: | |
Product Description
Aidear provides aluminum microchannel heat exchanger solutions for air-cooled condenser applications in HVAC and refrigeration systems.
Designed to transfer heat from refrigerant to ambient air, microchannel condenser coils use multiport flat tubes, fins, and refrigerant headers to create a compact heat transfer structure.
Compared with conventional round-tube fin-and-tube configurations, microchannel technology offers different possibilities for coil size, weight, and internal refrigerant volume. Actual performance depends on the selected design and operating conditions.
For OEM equipment manufacturers and refrigeration system integrators, Aidear supports the selection of microchannel condenser coils according to application requirements, installation dimensions, and operating parameters.
Multi-port flat tubes provide multiple refrigerant flow channels within a compact heat exchanger structure.
This design helps equipment manufacturers arrange condenser coils within limited installation space.
The combination of flat refrigerant tubes and external fins provides a heat exchange surface for heat exchange between the refrigerant and the surrounding air.
Thermal performance depends on the coil structure, refrigerant properties, airflow, and operating temperature.
Lightweight aluminum microchannel coils are suitable for certain types of HVAC and refrigeration equipment designs.
Material compatibility and environmental conditions should be considered when selecting products.
Microchannel coil designs can provide lower internal refrigerant volume than certain conventional fin-and-tube configurations.
The actual refrigerant charge depends on the condenser design and the complete refrigeration system.
Microchannel condenser coils can be evaluated based on equipment size, connection method, heat dissipation requirements, and installation conditions.
Specific project configurations require technical review and manufacturing feasibility assessment.
A typical aluminum microchannel condenser coil consists of several important components.
A flat tube contains multiple tiny internal channels through which the refrigerant flows within the heat exchanger.
The tube geometry and internal channel structure affect the refrigerant's pressure drop, distribution, and heat transfer.
Air-side fins increase the external surface area available for heat exchange.
The shape, spacing, and airflow conditions of the fins all affect heat transfer performance and air-side drag.
Headers distribute and collect refrigerant within the microchannel coil.
Header arrangement and refrigerant circuitry must be considered according to the intended condenser operating conditions.
Connection dimensions, locations, and interface requirements should be compatible with the refrigeration system design.
Connection details should be confirmed during the technology selection phase.
The following parameters should be confirmed according to the selected model or customized project requirements.
Parameter | Specification |
|---|---|
Product Type | Microchannel Condenser Coil |
Application | Air-Cooled Condenser |
Construction | Multiport Flat Tubes with Fins and Headers |
Material | Aluminum (Grade to Be Confirmed) |
Core Length | Project-Specific |
Core Height | Project-Specific |
Core Thickness | Project-Specific |
Fin Pitch | To Be Confirmed |
Refrigerant Compatibility | To Be Verified |
Heat Rejection Capacity | According to Rated Operating Conditions |
Maximum Allowable Pressure | To Be Confirmed |
Connection Dimensions | According to Project Requirements |
Mounting Arrangement | To Be Confirmed |
Note: Final specifications, operating limits, and available configurations must be confirmed according to the actual product design and application requirements.
Microchannel condenser coils can be used as heat dissipation components in suitable air-cooled chiller configurations.
The required coil design depends on the condenser heat dissipation, refrigerant state, ambient air temperature, and fan performance.
Microchannel heat exchangers can be integrated into suitable commercial HVAC equipment, including packaged air conditioning systems and rooftop units.
Selection must account for installation space, airflow arrangement, refrigerant circuitry, and system operating conditions.
Microchannel condenser coils can be considered for use in air-cooled condensing units in refrigeration applications.
The suitability of the coil depends on refrigerant compatibility, operating pressure, required heat dissipation, and equipment configuration.
Microchannel heat exchanger coils may be evaluated for OEM refrigeration equipment requiring specific dimensions, connection interfaces, and thermal operating conditions.
Different HVAC and refrigeration systems have different condenser requirements.
For OEM manufacturers and system integrators, coil selection involves more than matching overall dimensions.
Aidear can review project requirements to discuss suitable microchannel heat exchanger configurations.
Core length, height, thickness, and available installation space should be considered to determine a suitable coil arrangement.
Required heat rejection capacity, condensing temperature, ambient temperature, refrigerant operating conditions, and airflow should be provided for thermal evaluation.
Refrigerant distribution, circuit arrangement, and allowable pressure drop are important considerations when evaluating a condenser coil configuration.
The connection location, interface size, installation method, and installation direction should be checked to ensure they are compatible with the existing equipment design.
Outdoor installation conditions, including humidity, airborne contaminants, and corrosive exposure, should be considered when reviewing material suitability and protection requirements.
Selecting a suitable microchannel condenser requires accurate information about the operating conditions and equipment layout.
To support technical evaluation, please provide the following information:
Refrigerant Type: Specify the refrigerant used in the system.
Required Heat Rejection Capacity: Provide the target condenser heat rejection in kW.
Condensing Temperature: Specify the design condensing temperature.
Ambient Temperature: Provide the design air inlet temperature.
Airflow: Specify available airflow or fan performance data.
Installation Dimensions: Provide the available length, height, and thickness.
Operating Pressure: Specify the relevant system operating and design pressure requirements.
Connection Requirements: Provide inlet and outlet connection details.
Application Information: Identify the equipment type and installation environment.
Existing coil drawings, equipment specifications, or reference samples can help with technical evaluation.
A microchannel condenser coil is a refrigerant-air heat exchanger that uses a flat tube containing multiple tiny refrigerant channels.
It transfers heat from the refrigerant to the surrounding air and can be used as a component of suitable air-cooled condenser equipment.
Microchannel coils generally use multiport flat tubes, while conventional fin-and-tube coils typically use round tubes with external fins.
The two constructions differ in refrigerant flow passages, internal volume, and heat transfer geometry.
The appropriate choice depends on the application, system design, operating conditions, maintenance requirements, and total equipment considerations.
Refrigerant compatibility depends on the coil materials, construction, operating pressure, temperature, and system requirements.
Compatibility must be confirmed for the specific refrigerant before selection.
Replacement may be possible after evaluating thermal capacity, pressure drop, airflow, refrigerant compatibility, connection dimensions, and installation requirements.
A direct replacement should not be assumed based on external dimensions alone.
Please provide the refrigerant, required heat rejection capacity, design temperatures, airflow, available installation dimensions, and connection requirements.
Technical drawings or existing product specifications are also helpful.
Looking for a microchannel heat exchanger for your air-cooled condenser, HVAC system, or refrigeration equipment?
Contact Aidear with your technical requirements, operating conditions, and installation drawings.
Our team can review your project information and discuss suitable microchannel condenser coil options.