AD-A2610-04
Aidear
Aluminium
220V-460V
Up to 1.5MPa
30 kg
12 months
Plate Fin Heat Exchanger
-40°C ~+150°C
Heating / Cooling / Condensation / Evaporation / Heat Recovery
Wind Energy, Solar Energy Industry, Smart Grid, Semiconductors, SVG, SVC, DC-DC Converter, Cabine
| Availability: | |
|---|---|
| Quantity: | |
Product Description
Small in Size. Engineered for Efficient Heat Transfer.
When installation space is limited, every component matters.
Aidear's Small Plate Fin Heat Exchanger provides a compact aluminum heat transfer solution for industrial equipment and customized cooling systems.
By combining a finned heat transfer surface with a space-efficient core structure, this design helps equipment manufacturers integrate thermal management into restricted installation areas without unnecessarily increasing equipment size.
Whether developing a new cooling module or replacing an existing heat exchanger, Aidear offers design options based on your actual thermal requirements and installation constraints.
Compact Structure | Lightweight Design | Custom Configurations | OEM Integration
Not every industrial cooling application requires a large heat exchanger.
For compact machinery, integrated cooling modules and space-constrained equipment, oversized components can create installation difficulties, complicated piping arrangements and unnecessary packaging challenges.
Our small plate fin heat exchanger is designed with these limitations in mind.
A compact core structure provides substantial heat transfer surface area within a relatively small package.
This makes plate fin technology a practical option when equipment dimensions are restricted but thermal management remains essential.
Aluminum construction offers a favorable combination of thermal conductivity and low material weight.
For equipment manufacturers, a lightweight heat exchanger can simplify component integration and help reduce the overall weight of the cooling assembly.
Heat exchanger selection should consider more than external dimensions.
Connection positions, airflow direction, mounting requirements and service access must also fit the equipment layout.
Aidear can review these requirements when developing a customized compact heat exchanger.
The performance of a small heat exchanger depends on how effectively its available space is used.
The plate fin structure incorporates closely arranged fins that increase the surface area available for thermal exchange.
Heat transfers between separated fluid streams through the metal surfaces, while the fin geometry helps determine thermal performance and flow resistance.
Flow channel arrangement plays an important role in heat exchanger design.
Different fin geometries and passage configurations can influence:
Heat transfer performance
Fluid flow distribution
Pressure drop
Overall core dimensions
Suitability for different operating conditions
The appropriate configuration depends on the cooling medium, flow rate, temperature requirements and available installation space.
An effective compact cooling core must connect properly to the surrounding equipment.
Inlet and outlet arrangements, headers and mounting features can be evaluated according to the selected heat exchanger configuration.
Choosing a small heat exchanger is not simply about selecting the smallest available model.
A suitable design must balance installation dimensions, thermal duty and flow resistance.
Every cooling system has physical limitations.
Before finalizing the exchanger dimensions, the available installation length, width and height should be established.
The required space includes not only the heat exchanger core but also:
Connection and piping clearance
Mounting provisions
Airflow clearance where applicable
Maintenance access
A compact heat exchanger should fit the complete equipment arrangement, not just the available mounting surface.
A smaller core must still provide the necessary cooling performance.
Heat exchanger selection should consider the required heat duty, fluid temperatures, flow rates and allowable pressure drop.
Reducing core dimensions without reviewing these parameters may compromise thermal performance.
Restricted flow passages can increase fluid resistance.
The final fin and channel arrangement should therefore be evaluated against the available pump or fan performance and the system's pressure-drop limits.
Different cooling systems operate with different fluids and environmental conditions.
The suitability of aluminum and the selected heat exchanger construction should be reviewed according to fluid chemistry, operating temperature and pressure.
Fluid compatibility is particularly important for cooling applications involving additives, oils or corrosive environments.
Connection layout can significantly affect how easily a compact heat exchanger integrates into existing equipment.
Depending on engineering feasibility, customization may include:
Connection locations
Inlet and outlet sizes
Core orientation
Mounting brackets
External dimensions
These features help align the exchanger with the actual mechanical requirements of the cooling system.
Compact plate fin heat exchangers are suitable for a variety of industrial thermal management applications, subject to the specified operating conditions.
Designed for cooling assemblies where available space is limited and heat must be transferred efficiently between operating media.
Suitable configurations can be developed for equipment requiring heat removal from hydraulic or lubrication oil circuits, subject to fluid compatibility, pressure and cooling-duty requirements.
Compact heat exchanger cores may be integrated into compressor-related auxiliary cooling circuits to manage operating temperatures within the required design limits.
For machinery manufacturers, compact heat exchanger dimensions and connection arrangements can be developed around specific equipment layouts.
One Compact Core. Multiple Integration Possibilities.
Standard heat exchanger dimensions may not suit every equipment design.
Aidear supports customized heat exchanger selection based on specific application requirements.
Design Item | Customization Scope |
|---|---|
Core Dimensions | Length, width and height |
Fin Configuration | Selected according to thermal and hydraulic requirements |
Flow Arrangement | Based on the intended operating media |
Connection Design | Size, position and orientation |
Mounting Arrangement | According to installation requirements |
Operating Conditions | Temperature, pressure and flow requirements |
Final configurations are subject to engineering review and manufacturing feasibility.
To help determine a suitable compact plate fin heat exchanger, please share the following information.
Required cooling capacity or heat duty
Hot-side and cold-side fluids
Fluid inlet temperatures
Required outlet temperatures
Flow rates
Maximum available installation dimensions
Operating and design pressure
Allowable pressure drop
Preferred connection sizes and locations
Equipment drawings, if available
If you are replacing an existing heat exchanger, product photos, dimensions and operating information can help clarify the replacement requirements.
The required size depends on the thermal duty and operating conditions. A properly selected compact heat exchanger can meet a specified cooling requirement, but a smaller unit is not automatically a suitable replacement for a larger one.
Core dimensions and related structural features can be reviewed for customization according to the required thermal performance and manufacturing feasibility.
Yes. Suitable plate fin configurations can be designed for certain oil-cooling applications. Fluid properties, operating pressure, temperature and cooling requirements must be evaluated before selection.
Please provide the application, cooling capacity, fluid types, operating temperatures, flow rates, pressure requirements and available installation dimensions.
Your Equipment Has Limited Space. Your Cooling Solution Should Fit.
Looking for a compact plate fin heat exchanger that matches your equipment design?
Aidear provides application-based heat exchanger selection and customized solutions for industrial cooling requirements.
Send us your equipment specifications or technical drawings to discuss a suitable compact heat transfer solution.