AD-A2610-05
Aidear
Aluminium
220V-460V
Up to 1.5MPa
100 kg
12 months
Plate Fin Heat Exchanger
-40°C ~+150°C
Fluid Cooling / Heat Rejection
Wind Energy, Solar Energy Industry, Smart Grid, Semiconductors, SVG, SVC, DC-DC Converter, Cabine
| Availability: | |
|---|---|
| Quantity: | |
Product Description
Compact Cooling Solution for Rotary Screw Air Compressors
Aidear's Air Compressor Oil Cooler is an air-to-oil heat exchanger designed to remove excess heat from lubricating oil in industrial air compressor systems.
Featuring an aluminum plate-fin structure, the cooler provides a large heat transfer surface within a compact core. When integrated with a suitable forced-air cooling system, it transfers heat from circulating compressor oil to the surrounding air.
The oil cooler can be configured for OEM equipment integration or replacement applications, with dimensions and connections evaluated according to the compressor's operating requirements.
Compact Design | Air-to-Oil Cooling | OEM Customization | Application-Based Selection
Oil temperature management is an important part of reliable compressor operation.
In oil-injected rotary screw compressors, lubricating oil performs several essential functions, including lubrication, sealing and heat removal. During operation, the oil absorbs heat and must be cooled before continuing through the lubrication and injection circuit.
Choosing the right oil cooler helps remove heat from the circulating compressor oil and maintain the required operating temperature range.
Effective oil temperature control helps ensure proper lubrication and helps prevent operational problems caused by excessively high oil temperatures.
Industrial air compressors typically operate for extended periods under varying loads and environmental conditions.
The cooling system must be able to handle the required heat dissipation load while maintaining acceptable oil-side pressure drop and airflow resistance.
The aluminum plate-fin design provides a larger heat exchange area within a relatively compact structure.
This makes the design suitable for compressor manufacturers with space constraints and the need for integrated cooling components.
Plate-fin cooling cores employ closely spaced fins and internal flow channels to increase the effective heat exchange area.
This design enables heat exchange within a compact structure and supports integration into industrial compressor cooling systems.
The cooler transfers heat from the compressor lubricating oil to the surrounding air.
With a suitable fan and airflow arrangement, this system can achieve oil cooling without requiring a separate cooling water circuit for the heat exchanger.
The heat exchanger geometry should be matched to the required oil flow rate, cooling load, operating temperature, and permissible pressure drop.
Core dimensions, fin arrangement, and flow channels can be evaluated based on the specific compressor application.
Connection dimensions, orientation, and location are crucial for integration into the compressor's oil circuitry.
Aidear can review available connection configurations and installation requirements based on customer drawings or equipment specifications.
The oil cooler removes heat from hot lubricating oil by transferring thermal energy to air flowing through the heat exchanger.
Hot lubricating oil enters the cooler through an inlet connection and flows through the internal oil passages.
Heat is transferred from the oil to the metal walls and fin structure. The cooled oil then leaves the outlet and returns to the compressor oil circuit according to the system design.
Cooling air passes across the external finned surfaces, typically driven by a fan integrated into the compressor cooling assembly.
The temperature difference between the hot oil and cooling air provides the driving force for heat transfer.
The cooling performance of a plate-fin oil cooler is influenced by:
Oil inlet temperature and required outlet temperature
Oil flow rate and thermophysical properties
Ambient air temperature
Cooling airflow and fan performance
Heat exchanger surface area and fin configuration
Oil-side and air-side pressure losses
Higher flow resistance increases the load on the oil circulation system or reduces fan airflow.
A proper heat exchanger design must balance the required cooling load, the allowable oil-side pressure drop, and the availability of the fan.
Therefore, heat capacity, flow resistance, and core dimensions should be evaluated comprehensively, rather than individually.
The primary application is lubricating oil cooling in oil-injected rotary screw air compressors.
The cooler removes heat absorbed by the oil during compression and helps maintain the required oil temperature before recirculation.
Aluminum finned oil coolers can be integrated into air-cooled industrial compressor units, provided that the dimensions of the cooling components conform to the specified equipment dimensions.
The choice depends on the compressor's lubrication circuit, operating conditions, and cooling requirements.
For compressor equipment manufacturers, the heat exchanger can be evaluated as part of a customized cooling assembly.
Core dimensions, oil connections, mounting arrangements and airflow direction can be reviewed for integration into new compressor designs.
When replacing the oil cooler in an existing air compressor, an evaluation should be conducted based on the original cooler's cooling load, dimensions, connection method, operating pressure, and pressure drop.
Providing drawings or operating information of the original cooler will help determine a suitable replacement.
Different air compressors require different cooling capacities, oil flow rates and installation arrangements.
Aidear supports application-based heat exchanger selection for customers requiring customized oil cooling solutions.
Design Item | Available Design Considerations |
|---|---|
Core Dimensions | Length, width and thickness |
Fin Configuration | Based on cooling and airflow requirements |
Oil Connections | Connection size, location and orientation |
Header Arrangement | According to circuit and installation requirements |
Mounting Configuration | Evaluated from equipment drawings |
Cooling Performance | Selected for specified operating conditions |
Oil Flow Passages | Evaluated for flow distribution and pressure drop |
All custom configurations are subject to technical review and manufacturing feasibility.
Selecting an air compressor oil cooler requires more than matching the external dimensions.
To evaluate a suitable plate-fin heat exchanger, the following information should be provided.
Compressor lubricant type and grade
Oil inlet temperature
Required oil outlet temperature
Oil flow rate
Operating and maximum design pressure
Maximum allowable oil-side pressure drop
Ambient air temperature
Available cooling airflow
Airflow direction
Fan operating information, if available
Installation clearance and ventilation conditions
Maximum available core dimensions
Connection type and size
Inlet and outlet positions
Mounting arrangement
Existing cooler drawing or sample
Required order quantity
These details help determine the required heat transfer area, flow arrangement and mechanical configuration.
Air compressor oil coolers are used to remove excess heat from the circulating lubricating oil.
In oil-injected screw compressors, lubricating oil serves to lubricate, seal, and cool. As part of the compressor's thermal management system, heat exchangers help control oil temperature.
Yes. Aluminum plate-fin heat exchangers are used in industrial air compressor oil cooling applications.
However, the selected cooler must be compatible with the lubricant and meet the required temperature, pressure, flow and thermal performance conditions.
No. An oil cooler removes heat from lubricating oil, while a compressed air aftercooler reduces the temperature of compressed air.
Some compressor cooling assemblies combine both functions within separate sections of an integrated heat exchanger. The internal circuit arrangement must be confirmed for each product.
Customization can be evaluated based on the original cooler dimensions, connection positions and operating requirements.
Customers can provide technical drawings, product photographs and compressor operating data for engineering review.
The required cooling duty, oil temperatures, oil flow rate, ambient conditions, pressure requirements and available installation space should be established first.
The heat exchanger can then be evaluated for both thermal performance and acceptable pressure losses.
Please provide the compressor application, required cooling capacity, oil type, operating temperatures, oil flow rate, pressure requirements, installation dimensions and quantity.
For replacement projects, an existing cooler drawing or clear photographs with dimensions are also helpful.
Looking for a Plate Fin Oil Cooler That Fits Your Compressor?
Whether you are developing a new compressor cooling system or replacing an existing oil cooler, Aidear can review your technical requirements and discuss suitable heat exchanger configurations.
Send us your compressor specifications, operating conditions or existing cooler drawings to request a technical review and quotation.
Request a Custom Quote | Contact Aidear Today