Vigezo vya utendaji
Mfano Urefu wa msingi Urefu wa msingi Unene wa bomba la gorofa Msimamo wa mwisho Urefu wa mwisho Mtoza kipenyo cha nje
SC-1000 333.2[mm] 299.7[mm] 16[mm] 1.1[mm] 8.1[mm] 20[mm]
13.12[katika] 11.8[katika] 0.63[katika] 23[FPI] 0.32[katika] 0.79[katika]

Mfano Urefu wa bomba la gorofa Idadi ya zilizopo za gorofa kitanzi Kiasi cha ndani Ingiza kipenyo cha ndani Kipenyo cha ndani cha nje
SC-1000 1.3[mm] 29 6/6/5/5/4/3 0.16[L] 6.35[mm] 6.35[mm]
0.05[katika] 9.5[katika 3] 1/4[katika] 1/4[katika]

Ufungaji wa Paneli ya Upande

Wabadilishaji wa joto wa kituo kidogo cha alumini hupanua na kupunguzwa kwa joto la juu, kwa hivyo ufungaji wa mabano na mambo mengine lazima uruhusu uvumilivu fulani.

 
Vigezo vya utendaji

Kasi ya upepo Utendaji wa uhamishaji joto [KW/Btu/h×1000]
[m/s] [ft/dakika] R410A R134a
△  =10K
△  =18°F
△  =15K
△  =27°F
△  =2K
△  =36°F
△  =25K
△  =45°F
△  =10K
△  =18°F
△  =15K
△  =27°F
△  =2K
△  =36°F
△  =25K
△  =45°F
1 197 0.88/3.00 1.37/4.68 1.85/6.31 2.33/7.95 0.83/2.83 1.27/4.33 1.72/5.87 2.20/7.51
1.5 295 1.2/4.10 1.91/6.52 2.58/8.81 3.26/11.13 1.12/3.82 1.73/5.90 2.40/8.19 3.00/10.24
2 394 1.54/5.26 2.39/8.16 3.23/11.02 4.08/13.92 1.37/4.68 2.12/7.24 2.96/10.10 3.70/12.63
2.5 492 1.82/6.21 2.81/9.59 3.80/12.97 4.82/16.45 1.58/5.39 2.54/8.67 3.43/11.71 4.30/14.68
3 591 2.07/7.06 3.2/10.92 4.33/14.78 5.49/18.74 1.77/6.04 2.86/9.76 3.86/13.17 4.80/16.38


Kasi ya upepo Utendaji wa uhamishaji joto [KW/Btu/h×1000]
[m/s] [ft/dakika] R404A R407C
△  =10K
△  =18°F
△  =15K
△  =27°F
△  =2K
△  =36°F
△  =25K
△  =45°F
△  =10K
△  =18°F
△  =15K
△  =27°F
△  =2K
△  =36°F
△  =25K
△  =45°F
1 197 0.86/2.94 1.37/4.68 1.85/6.31 2.33/7.95 0.57/1.95 1.08/3.69 1.55/5.29 2.06/7.03
1.5 295 1.18/4.03 1.9/6.48 2.56/8.74 3.23/11.02 0.76/2.59 1.47/5.02 2.19/7.47 2.87/9.80
2 394 1.5215.19 2.35/8.02 3.18/10.85 4.02/13.72 0.93/3.17 1.81/6.18 2.73/9.32 3.56/12.15
2.5 492 1.78/6.08 2.75/9.39 3.72/12.70 4.71/16.08 1.07/3.65 2.2/7.51 3.2/10.92 4.17/14.23
3 591 2.01/6.86 3.11/10.6 4.2/14.33 5.33/18.19 1.19/4.06 2.5/8.53 3.6/12.29 4.72/16.11

Data ya kushuka kwa shinikizo la upande wa hewa

Kasi ya upepo Kushuka kwa shinikizo Kiasi cha hewa
[m/s] [ft/dakika] [Pa]
[inchi H 2O] [m 3/ h]
[cfm]
1 197 9.12
0.04 313.30
184.3
1.5 295 14.35
0.06 470.00
276.5
2 394 21.82
0.09 626.52
368.5
2.5 492 29.20
0.12 783.15
460.7
3 591 34.9
50.14 939.78
552.8


Iliyotangulia: 
Inayofuata: 

Je, Huwezi Kupata Suluhu Bora za Mfumo wa Majokofu kwa Viwanda Vyako?

Sisi ni watoa huduma bora wa mfumo wa friji kwa karibu miaka 20, bidhaa zetu kuu ni vipimo mbalimbali vya kubadilishana joto, baridi ya hewa, condenser na vitengo, ambavyo vyote vinashughulikia eneo kubwa la matumizi.
Simu
 
+86 13915061591
Anwani
 
Sekta ya Maendeleo ya Teknolojia ya Juu na Mpya ya Wujin, Changzhou, Jiangsu, China

Bidhaa

Huduma

Kuhusu Sisi

Viungo

© COPYRIGHT 2025 CHANGZHOU AIDEAR REFRIGERATION TECHNOLOGY CO., LTD. HAKI ZOTE IMEHIFADHIWA.