Parameter kinerja
| Model |
Panjang inti |
Tinggi inti |
Ketebalan tabung datar |
Nada sirip |
Tinggi sirip |
Diameter luar kolektor |
| SC-1000 |
333,2[mm] |
299,7[mm] |
16[mm] |
1.1[mm] |
8.1[mm] |
20[mm] |
| 13.12[dalam] |
11.8[dalam] |
0,63[dalam] |
23[FPI] |
0,32[dalam] |
0,79[dalam] |
| Model |
Tinggi tabung datar |
Jumlah tabung datar |
lingkaran |
Volume bagian dalam |
Diameter dalam saluran masuk |
Diameter dalam saluran keluar |
| SC-1000 |
1,3[mm] |
29 |
6/6/5/5/4/3 |
0,16[L] |
6,35[mm] |
6,35[mm] |
| 0,05[dalam] |
9,5 [dalam 3] |
1/4 [dalam] |
1/4 [dalam]
|
Pemasangan Panel Samping
Penukar panas saluran mikro aluminium mengembang dan berkontraksi pada suhu tinggi, sehingga pemasangan braket dan aspek lainnya harus memberikan toleransi tertentu.

Parameter kinerja
| Kecepatan angin |
Performa perpindahan panas [KW/Btu/h×1000] |
| [MS] |
[kaki/menit] |
R410A |
R134a |
△ =10K △ =18°F |
△ =15K △ =27°F |
△ =2K △ =36°F |
△ =25K △ =45°F |
△ =10K △ =18°F |
△ =15K △ =27°F |
△ =2K △ =36°F |
△ =25K △ =45°F |
| 1 |
197 |
0,88/3,00 |
1.37/4.68 |
1.85/6.31 |
2.33/7.95 |
0,83/2,83 |
1.27/4.33 |
1.72/5.87 |
2.20/7.51 |
| 1.5 |
295 |
1.2/4.10 |
1.91/6.52 |
2.58/8.81 |
3.26/11.13 |
1.12/3.82 |
1,73/5,90 |
2.40/8.19 |
3.00/10.24 |
| 2 |
394 |
1.54/5.26 |
2.39/8.16 |
3.23/11.02 |
4.08/13.92 |
1.37/4.68 |
2.12/7.24 |
2.96/10.10 |
3.70/12.63 |
| 2.5 |
492 |
1.82/6.21 |
2.81/9.59 |
3.80/12.97 |
4.82/16.45 |
1.58/5.39 |
2.54/8.67 |
3.43/11.71 |
4.30/14.68 |
| 3 |
591 |
2.07/7.06 |
3.2/10.92 |
4.33/14.78 |
5.49/18.74 |
1.77/6.04 |
2.86/9.76 |
3.86/13.17 |
4.80/16.38 |
| Kecepatan angin |
Performa perpindahan panas [KW/Btu/h×1000] |
| [MS] |
[kaki/menit] |
R404A |
R407C |
△ =10K △ =18°F |
△ =15K △ =27°F |
△ =2K △ =36°F |
△ =25K △ =45°F |
△ =10K △ =18°F |
△ =15K △ =27°F |
△ =2K △ =36°F |
△ =25K △ =45°F |
| 1 |
197 |
0,86/2,94 |
1.37/4.68 |
1.85/6.31 |
2.33/7.95 |
0,57/1,95 |
1.08/3.69 |
1,55/5,29 |
2.06/7.03 |
| 1.5 |
295 |
1.18/4.03 |
1.9/6.48 |
2.56/8.74 |
3.23/11.02 |
0,76/2,59 |
1.47/5.02 |
2.19/7.47 |
2.87/9.80 |
| 2 |
394 |
1.5215.19 |
2.35/8.02 |
3.18/10.85 |
4.02/13.72 |
0.93/3.17 |
1.81/6.18 |
2.73/9.32 |
3.56/12.15 |
| 2.5 |
492 |
1.78/6.08 |
2.75/9.39 |
3.72/12.70 |
4.71/16.08 |
1.07/3.65 |
2.2/7.51 |
3.2/10.92 |
4.17/14.23 |
| 3 |
591 |
2.01/6.86 |
3.11/10.6 |
4.2/14.33 |
5.33/18.19 |
1.19/4.06 |
2.5/8.53 |
3.6/12.29 |
4.72/16.11 |
Data penurunan tekanan sisi udara
| Kecepatan angin |
Penurunan tekanan |
Volume udara |
| [MS] |
[kaki/menit] |
[Pa]
|
[inci H 2O] |
[m 3/ jam]
|
[cfm] |
| 1 |
197 |
9.12
|
0.04 |
313.30
|
184.3 |
| 1.5 |
295 |
14.35
|
0.06 |
470.00
|
276.5 |
| 2 |
394 |
21.82
|
0.09 |
626.52
|
368.5 |
| 2.5 |
492 |
29.20
|
0.12 |
783.15
|
460.7 |
| 3 |
591 |
34.9
|
50.14 |
939.78
|
552.8 |