Mfano Urefu wa Msingi Urefu wa Msingi Unene wa bomba la gorofa Fin Pitch Urefu wa Fin Kipenyo cha Nje cha Mbalimbali
SC-1900 1274[mm] 1358[mm] 25.4[mm] 1.1[mm] 8[mm] 38[mm]
50.16[katika] 53.46[katika] 1[katika] 23[FPI] 0.31[katika] 1.5[katika]



Mfano Urefu wa bomba la gorofa Idadi ya Mirija ya Gorofa Mzunguko Kiasi cha Ndani Ingizo Ndani ya Kipenyo Outlet Ndani ya Kipenyo
SC-1900 2[mm] 133 85/48 9.22[L] 22.2[mm] 22.2[mm]
0.08[katika] 562.6[katika 3] 7/8[katika] 7/8[katika]


Ufungaji wa Jopo la Upande
Vibadilishaji joto vya Alumini microchannel hupanua na mkataba kwa joto la juu, hivyo uvumilivu fulani lazima uruhusiwe kwa ajili ya ufungaji wa mabano na vipengele vingine.
 

Vigezo vya Utendaji

Kasi ya Hewa Utendaji wa Uhamishaji Joto [KW/Btu/h×1000]
[m/s] [ft/dakika] R410A R134a
△  =10K
△  =18°F
△  =15K
△  =27°F
△  =2K
△  =36°F
△  =25K
△  =45°F
△  =10K
△  =18°F
△  =15K
△  =27°F
△  =2K
△  =36°F
△  =25K
△  =45°F
1 197 17.88/61.02 27.51/93.89 37.6/128.33 47.57/162.35 17.51/59.76 26.74/91.26 35.94/122.66 45.05/153.75
1.5 295 25.34/86.48 39.1/133.45 54.12/184.71 68.52/233.86 24.71/84.33 37.89/129.32 51.02/174.13 65.29/222.83
2 394 32.02/109.28 51/174.06 69.32/236.59 87.84/299.8 31.08/106.08 47.91/163.52 66.08/225.53 83.43/284.74
2.5 492 38.08/129.97 61.35/209.39 83.45/284.81 105.85/361.2 36.89/125.9 57/194.54 79.29/270.61 99.92/341.02
3 591 43.63/148.91 70.98/242.25 96.64/329.83 122.69/418.7 42.23/144.13 65.32/222.94 91.49/312.25 115.27/393.4


Kasi ya Hewa Utendaji wa Uhamishaji Joto [KW/Btu/h×1000]
[m/s] [ft/dakika] R404A R407C
△  =10K
△  =18°F
△  =15K
△  =27°F
△  =2K
△  =36°F
△  =25K
△  =45°F
△  =10K
△  =18°F
△  =15K
△  =27°F
△  =2K
△  =36°F
△  =25K
△  =45°F
1 197 17.88/61.02 27.45/93.69 37.95/129.52 47.9/163.48 11.26/38.43 22.38/76.38 32.18/109.83 41.91/143.04
1.5 295 25.06/85.53 40.17/137.1 54.41/185.7 68.87/235.05 16.69/56.96 31.64/107.99 45.69/155.94 60.83/207.61
2 394 31.4/107.17 51.3/175.09 69.61/237.58 88.15/300.85 20.84/71.13 39.98/136.45 59.4/202.73 77.85/265.7
2.5 492 37.63/128.43 61.45/209.73 83.62/285.39 105.98/361.71 24.54/83.75 47.42/161.84 71.35/243.52 93.49/319.08
3 591 45.38/154.88 71.04/242.46 96.62/329.76 122.6/418.43 27.83/94.98 54.46/185.87 82.51/281.6 108.16/369.15


Kushuka kwa Shinikizo la Upande wa Hewa

Kasi ya Hewa Kushuka kwa Shinikizo Kiasi cha Hewa
[m/s] [ft/dakika] [Pa]
[inchi H 2O] [m 3/ h]
[cfm]
1 197 18.8
0.08 5955.0
3502.9
1.5 295 29.7
0.12 8932.5
5254.4
2 394 46.1
0.19 11910
7005.9
2.5 492 59.8
0.24 14885
8755.9
3 591 74.2
0.30 17860
10505.9



Iliyotangulia: 
Inayofuata: 

Je, Huwezi Kupata Suluhu Bora za Mfumo wa Majokofu kwa Viwanda Vyako?

Sisi ni watoa huduma bora wa mfumo wa friji kwa karibu miaka 20, bidhaa zetu kuu ni vipimo mbalimbali vya kubadilishana joto, baridi ya hewa, condenser na vitengo, ambavyo vyote vinashughulikia eneo kubwa la matumizi.
Simu
 
+86 13915061591
Anwani
 
Wujin High na New Technology Development Sekta, Changzhou, Jiangsu, China

Bidhaa

Huduma

Kuhusu Sisi

Viungo

© COPYRIGHT 2025 CHANGZHOU AIDEAR REFRIGERATION TECHNOLOGY CO., LTD. HAKI ZOTE IMEHIFADHIWA.