Paglalarawan ng Produkto
Mga Teknikal na Parameter
| Modelo | Core Haba | Taas ng Core | Kapal ng Flat Tube | Fin Pitch | Taas ng Palikpik | Manifold Panlabas na Diameter |
| SC-2000 | 2000[mm] | 1058[mm] | 25.4[mm] | 1.1[mm] | 8[mm] | 38[mm] |
| 78.74[in] | 41.65[in] | 1[in] | 23[FPI] | 0.31[in] | 1.5[in] |
| Modelo | Flat Tube Taas | Bilang ng mga Flat Tubes | Circuit | Panloob na Dami | Inlet Inside Diameter | Outlet sa Loob na Diameter |
| SC-2000 | 2[mm] | 103 | 69/34 | ≈10.3[L] | 25.4[mm] | 22.2[mm] |
| 0.08[in] | ≈628.6[in 3] | 1[in] | 7/8[in] |
Pag-install ng side panel
Ang mga aluminum microchannel heat exchanger ay lalawak at kukurutin sa mataas na temperatura, kaya dapat pahintulutan ang isang tiyak na hanay ng tolerance para sa pag-install ng bracket, atbp.

Mga parameter ng pagganap
| Ang bilis ng hangin | Pagganap ng heat transfer [KW/Btu/h×1000] | ||||||||
| [MS] | [ft/min] | R410A | R134a | ||||||
| △ =10K △ =18°F |
△ =15K △ =27°F |
△ =2K △ =36°F |
△ =25K △ =45°F |
△ =10K △ =18°F |
△ =15K △ =27°F |
△ =2K △ =36°F |
△ =25K △ =45°F |
||
| 1 | 197 | 22.7/77.47 | 34.95/119.28 | 46.97/160.31 | 59.06/201.57 | 21.93/74.85 | 33.25/113.48 | 44.75/152.73 | 56.3/192.15 |
| 1.5 | 295 | 32.7/111.6 | 50.21/171.37 | 67.52/230.44 | 85/290.1 | 30.91/105.49 | 47.03/160.51 | 64.07/218.67 | 80.39/274.37 |
| 2 | 394 | 41.98/143.28 | 64.14/218.91 | 86.37/294.78 | 108.94/371.81 | 38.82/132.49 | 60.4/206.14 | 81.29/277.44 | 101.57/346.66 |
| 2.5 | 492 | 50.4/172.01 | 77.03/262.9 | 103.81/354.3 | 131.04/447.24 | 45.91/156.69 | 71.91/245.43 | 96.11/328.02 | 120.76/412.15 |
| 3 | 591 | 58.23/198.74 | 88.87/303.31 | 120.06/409.76 | 151.56/517.27 | 52.31/178.53 | 82.41/281.26 | 109.83/374.85 | 138.18/471.6 |
| Ang bilis ng hangin | Pagganap ng heat transfer [KW/Btu/h×1000] | ||||||||
| [MS] | [ft/min] | R404A | R407C | ||||||
| △ =10K △ =18°F |
△ =15K △ =27°F |
△ =2K △ =36°F |
△ =25K △ =45°F |
△ =10K △ =18°F |
△ =15K △ =27°F |
△ =2K △ =36°F |
△ =25K △ =45°F |
||
| 1 | 197 | 22.53/76.89 | 35.14/119.93 | 47.15/160.92 | 59.26/202.25 | 15.26/52.08 | 28.07/95.8 | 40.58/138.5 | 52.71/179.9 |
| 1.5 | 295 | 32.86/112.15 | 50.19/171.3 | 67.5/230.38 | 85/290.1 | 21.34/72.83 | 39.8/135.84 | 58.2/198.63 | 75.49/257.65 |
| 2 | 394 | 41.77/142.56 | 63.85/217.92 | 85.96/293.38 | 108.35/369.8 | 26.63/90.89 | 51.57/176.01 | 74.25/253.41 | 96.26/328.53 |
| 2.5 | 492 | 49.99/170.61 | 76.38/260.68 | 102.87/351.09 | 129.7/442.66 | 31.32/106.89 | 61.75/210.75 | 88.6/302.39 | 115.34/393.65 |
| 3 | 591 | 57.26/195.43 | 87.9/300 | 118.38/404.03 | 149.25/509.39 | 35.37/120.72 | 71.13/242.76 | 102/348.12 | 132.76/453.11 |
Data ng pagbaba ng presyon sa gilid ng hangin
| Bilis ng hangin | Pagbaba ng presyon | Dami ng hangin | |||
| [MS] | [ft/min] | [Pa] |
[pulgada HO 2] | [m 3/ h] |
[cfm] |
| 1 | 197 | 18.7 |
0.08 | 7330 |
4311.8 |
| 1.5 | 295 | 29.7 |
0.12 | 10995 |
6467.5 |
| 2 | 394 | 46 |
0.18 | 14660 |
8623.5 |
| 2.5 | 492 | 59.7 |
0.24 | 18330 |
10782.4 |
| 3 | 591 | 74 |
0.3 | 21995 |
12938.2 |