Kuna nan: Gida » Kayayyaki » Microchannel Heat Exchanger SC -1800 Condenser Coil Microchannel Heat Exchanger

lodi

Raba zuwa:
facebook button sharing
twitter sharing button
maɓallin raba layi
wechat sharing button
linkin sharing button
maballin rabawa pinterest
whatsapp sharing button
share wannan button sharing

SC-1800 Condenser Coil Microchannel Heat Exchanger

samuwa:
Yawan:

Bayanin Samfura

Ma'aunin Fasaha

Samfura Tsawon Mahimmanci Core Height Flat Tube Kauri Fin Fin Fin Tsawo Diamita Manifold Outer
Saukewa: SC-1800 1074[mm] 1208[mm] 25.4[mm] 1.1 [mm] 8 [mm] 38[mm]
42.28 [na] 47.56 1[in] 23[FPI] 0.31 [in] 1.5 [in]


Samfura Flat Tube Tsawo Adadin Tubbai Lebur kewaye Ƙarar Ciki Mashigar Ciki Diamita Fitar Ciki Diamita
Saukewa: SC-1800 2 [mm] 118 83/35 ≈7.18[L] 22.2[mm] 22.2[mm]
0.08 [in] ≈438.16[in 3] 7/8[in] 7/8[in]


Shigar da Panel Wuraren
Aluminum microchannel masu musayar zafi suna faɗaɗa kuma suna kwangila a yanayin zafi mai girma, don haka dole ne a ba da izinin wasu haƙuri don shigarwar sashi da sauran fannoni.
 

Ma'aunin Aiki

Gudun Jirgin Sama Ayyukan Canja wurin zafi [KW/Btu/h×1000]
[m/s] [ft/min] R410A R134 a
△  = 10K
△  = 18°F
△  = 15K
△  = 27°F
△  = 2K
△  = 36°F
△  = 25K
△  = 45°F
△  = 10K
△  = 18°F
△  = 15K
△  = 27°F
△  = 2K
△  = 36°F
△  = 25K
△  = 45°F
1 197 11.74/40.07 20.09/68.57 27.62/94.27 35.02/119.52 12.65/43.17 19.61/66.93 26.43/90.20 33.19/113.28
1.5 295 18.23/62.22 28.54/97.41 39.71/135.53 50.38/171.95 18.01/61.47 27.74/94.68 37.54/128.12 48.11/164.20
2 394 23.03/78.60 37.18/126.89 50.82/173.45 64.59/220.44 22.59/77.10 35.01/119.49 48.62/165.94 61.49/209.86
2.5 492 27.38/93.45 44.69/152.53 61.08/208.46 77.78/265.46 26.81/91.50 41.72/142.39 58.42/199.39 73.92/252.29
3 591 31.32/106.8 51.72/176.52 70.81/241.67 90.18/307.78 30.72/104.85 47.81/163.17 67.43/230.14 85.45/291.64


Gudun Jirgin Sama Ayyukan Canja wurin zafi [KW/Btu/h×1000]
[m/s] [ft/min] R404A R407C
△  = 10K
△  = 18°F
△  = 15K
△  = 27°F
△  = 2K
△  = 36°F
△  = 25K
△  = 45°F
△  = 10K
△  = 18°F
△  = 15K
△  = 27°F
△  = 2K
△  = 36°F
△  = 25K
△  = 45°F
1 197 13.02/44.44 20.13/68.70 27.91/95.26 35.29/120.44 8.23/28.09 16.31/55.67 23.61/80.58 60.43/206.25
1.5 295 18.21/62.15 29.42/100.41 40.03/136.62 50.71/173.07 11.03/37.65 22.97/78.40 33.451114.16 44.68/152.49
2 394 22.74/77.61 37.51/128.02 51.12/174.47 64.93/221.60 14.83/50.61 29.03/99.08 43.52/148.53 57.21/195.26
2.5 492 26.81/91.50 44.91/153.28 61.39/209.52 78.12/266.62 17.42/59.45 34.42/117.47 52.13/177.92 68.82/234.88
3 591 32.81/111.9 51.93/177.24 70.98/242.25 90.42/308.60 19.82/67.65 39.51/134.85 60.43/206.25 79.63/271.77


Saukar da Matsalolin Iska

Gudun Jirgin Sama Saukar da Matsi Girman Iska
[m/s] [ft/min] [Ba]
[inch H 2O] [m 3/h]
[cfm]
1 197 18.7
0.08 4425.0
2602.9
1.5 295 29.7
0.12 6635.0
3902.9
2 394 46.1
0.19 8845.0
5202.9
2.5 492 59.7
0.24 11055.0
6502.9
3 591 74.1
0.30 13265
7802.9



Na baya: 
Na gaba: 

Ba za a iya Nemo Mahimman Magance Tsarin Refrigeration Don Masana'antunku ba?

Mu ne mai kyau, ƙwararrun tsarin samar da mafita na tsarin sanyi na kusan shekaru 20, manyan samfuranmu sune ƙayyadaddun bayanai daban-daban na musayar zafi, mai sanyaya iska, na'ura da raka'a, waɗanda duk ke rufe babban yanki na aikace-aikacen.
Waya
 
+86 13915061591
Adireshin
 
Wujin High and New Technology Development Industry, Changzhou, Jiangsu, China

Kayayyaki

Ayyuka

Game da Mu

Hanyoyin haɗi

© COPYRIGHT 2025 CHANGZHOU AIDEAR REFRIGERATION TECHNOLOGY CO., LTD. DUKAN HAKKOKIN.